YONGHESHENG — Reliable Cable Insulation & Sheathing Compounds

Technical Data

Technical Specifications

Typical physical property data, subject to batch test reports.

NO.Test itemsUnitStandardTypical ValueTest Methods
1Tensile strengthMPa≥1416.5IEC811-1-1
2Elongation at break point%≥600810IEC811-1-1
3Volume electrical resistivity @20℃Ω·m≥1.0×10¹⁴8.5×10¹⁵IEC60093
4Limit oxygen index(LOI)%——GB/T1408.1-2006
5Thermal oven-aged @100℃×240h - The retaining of tensile strength%≥7098IEC811-1-1
5Thermal oven-aged @100℃×240h - The retaining of elongation%≥7095IEC811-1-1
6Impact Brittleness Temperature@-40℃—0/300/30IEC811-1-4
7Environmental required/Conformed to RoHS、REACHConformed to RoHS、REACH
8Densityg/cm³0.924 ±0.040.925GB/T1033-1986
9Hardness Shore D 15SecondShore D45 ±345GB2411-1980
⚠️ Data should not be specification work. In case of colored products, the values could vary slightly by color.
Recommended

Extrusion Process

Note: The temperature for cable extrusion should be set at the situation of good cable surface performance.

ZoneZone1Zone2Zone3Zone4NeckDieEye
Temperature / ℃130±5160±5170±5180±5190±5195±5200±5
Packaging & Storage

Packaging and storage

1

Storage

  • Package: 25kg per bag, Alumni-plastic inner, Kraft paper outside.
  • Storage: no rain, no direct sunlight. Dry it at 60℃~70℃ about 4 hours if the material was storage more than 3 months before used.
2

Suggestion for processing

  • The compression value of extrusion screw should be 1.5~2.5
  • The time of material heated in the barrel should not exceed 30mins, or it maybe decomposed.