YONGHESHENG — Reliable Cable Insulation & Sheathing Compounds

Technical Data

Technical Specifications

Typical physical property data, subject to batch test reports.

NO.Test itemsUnitStandardTypical ValueTest Methods
1Tensile strengthMPa≥2526ISO572-2
2Elongation at break point%≥700850
3Volume electrical resistivity @20 ℃Ω·cm≥1.0×10¹⁶8.5×10¹⁷IEC 60502
4Dielectric strengthkV/mm≥2539IEC 60243
5MFR@190 ℃×2.16kgg/10min≤2.00.5IEC60093
6Thermal stress @115 ℃×6h%≤101.5IEC60811-508
7Low-temperature embrittlement temperature @ -76 ℃℃-76PassASTM D746
8ESCR(50 ℃,Igepal 10%,F0)h≥5000PassIEC60811-406
9Carbon black content%2.60 ±0.252.61IEC60811-605
10Carbon black dispersionGrade≤3PassISO 18553
11Oxidation induction period at 200 ℃min≥30PassIEC60811-509
12Densityg/cm³0.965 ±0.050.965GB/T1033-1986
13Hardness Shore D 15SecondShore D61 ±360GB2411-1980
⚠️ Data should not be specification work. In case of colored products, the values could vary slightly by color.
Recommended

Extrusion Process

Note: The temperature for cable extrusion should be set at the situation of good cable surface performance.

Zone1Zone2Zone3Zone4NeckDieEye
150 ±10170 ±10180 ±10190 ±10200 ±10210 ±10220 ±10
Packaging & Storage

Packaging and storage

1

Storage

  • Package: 25kg per bag, Alumni-plastic inner, Kraft paper outside.
  • Storage: no rain, no direct sunlight. Dry it at 70℃~80℃ about 4 hours if the material was storage more than 3 months before used.
2

Suggestion for processing

  • The compression value of extrusion screw should be 2.5~3.5
  • The time of material heated in the barrel should not exceed 30mins, or it maybe decomposed.