Technical Data
Technical Specifications
Typical physical property data, subject to batch test reports.
| No | Test Item | Unit | Typical | Test Standard | Test Category |
|---|---|---|---|---|---|
| 1 | Density | g/cm3 | 0.89 | GB/T 1033.1 | T, S |
| 2 | Tensile Strength | MPa | 30 | GB/T 1040.3 | T, S |
| 2 | Elongation at Break | % | 660 | GB/T 1040.3 | T, S |
| 3 | UL thermal aging | 113℃×168h | GB/T 1040.3 UL 2556 | T | |
| 3 | Change rate of tensile strength | % | 10 | GB/T 1040.3 UL 2556 | T |
| 3 | Change rate of elongation at break | % | -15 | GB/T 1040.3 UL 2556 | T |
| 4 | Volume resistivity at 20 ℃ | Ω·m | 7×10¹⁴ | GB/T 31838.2 | T, S |
| 5 | -40 ℃ Impact Brittleness | Failure count | 0/30 | GB/T 5470 | T |
⚠️ Note 1: Typical values are representative values in actual testing, for reference only, and cannot be used as standards for judgment.
Recommended
Extrusion Process
(1) The extruder and head should ensure that the maximum heating temperature can meet ≥ 250℃
(2) When the extruder is placed for a long time or after several days of continuous production, the equipment should be cleaned immediately
(3) If the conditions are met, it needs to be dried at 70 ℃ for at least 4 hours before use
(4) The recommended process temperature is as follows, and adjustments should be made in a timely manner according to the actual situation of equipment and discharge
| 1 | 2 | 3 | 4 | 5 | 6 | Net | Head | |
|---|---|---|---|---|---|---|---|---|
| 135 | 160 | 170 | 180 | 190 | 190 | 195 | 200 | 200 |