Technical Data

Technical Specifications

Typical physical property data, subject to batch test reports.

No.Test ItemTest MethodTest ConditionUnitRequirementsValues
1Tensile Strength2PfG 2962at 20±3℃N/mm2≥814.2
2Elongation at Break2PfG 2962at 20±3℃%≥125295
After air oven accelerated aging150℃×168h
3Tensile Strength; Percent of unaged value2PfG 2962at 20±3℃%≥75105
Elongation at Break; Percent of unaged value2PfG 2962at 20±3℃%≥7591
Hot set test200±3℃, 15min , 20N/cm2
4Hot2PfG 2962at 20±3℃%≤10040
Set2PfG 2962at 20±3℃%≤250
5Voltage test on completed cable2PfG 2962AC, 6.5kV, 5min, at 20℃ waterNo breakdownNo breakdown
6Insulation resistance at 20℃2PfG 296215m , 6hMΩ•km≥70912600
7Insulation resistance at 90℃2PfG 296215m , 6hMΩ•km≥0.709112
8Cold bending test2PfG 2962-40℃, 16h-No CrackNo Crack
Test of absence of halogen
PHEN50267-2-2-≥4.36.1
9ConductivityEN50267-2-2μS/mm≤100.9
Chlorine- and Bromine content, expressed in HClEN50525-1%≤0.50
ConductivityEN60684-2%≤0.10
⚠️ Mix the A and B Component evenly, drop them into the hopper. Please use EVA masterbatch if color required(it should be dry). The material must be use up within 2 hours after unpacking.(It can’t be dried.)Avoid to bring the external water in during the process.
Processing Guide

Recommended Processing Parameters

1

Material Composition

  • By the polyolefin materials, filler, stabilizer, lubricant inside and outside through special proportion, end spacing refining and added to the mix and twin-screw granulating of halogen-free insulating materials.
2

Processing

  • Drying and dehumidification: Dry the compounds at 70℃ for at least 2 hours by air blast and the dehumidifier before processing.
  • Extrusion machine parameters: It is recommended to use an extruder with a length-to-diameter ratio of 25:1 for extrusion. The screw compression ratio is 1.5- 1.8:1.
  • Extrusion cooling conditions: Every cooling system of extrusion molding machine must be able to work automatically ,feed opening must be cooled with water.
  • Conductors preheating: Preheating temperature is 65℃--85℃;
3

Irradiation process

  • Irradiation dose: Recommendation irradiation dose is 10-20 Mrad;
  • The irradiation dose should be adjusted according to the product structure and specification difference.
  • Due to the influence of the difference of electron accelerators on the measurement, the selection of radiation dose should be based on the test thermal extension meeting the requirements. It is suggested that the dose should be used for reference only, and the thermal extension should be controlled in the range of 30-60%.
4

Inspection Requirements

  • Appearance: Visual inspection and hand inspection, polymer particle diameter is 3~5mm.
  • Properties: Annex I and Annex II