Data
Application
| Trade Mark | A:B | Product Name | Application |
|---|---|---|---|
| YHS-EPR65 | 95:5 | 105℃ Silane crosslinked Polyolefin Elastomer Cable Material | Suit for the insulation of cables up to 3kV |
| YHS-EPR80 | 95:5 | 105℃ Silane crosslinked Polyolefin Elastomer Cable Material | Suit for the insulation of cables up to 3kV |
| YHS-EPR85 | 95:5 | 105℃ Silane crosslinked Polyolefin Cable Material | Suit for the insulation of cables rated up to 3kV |
| YHS-EPR90 | 95:5 | 105℃ silane cross-linked polyolefin elastomer cable material | It is suitable for cable insulation layer of 3KV and below |
Technical Data
Technical Specifications
Typical physical property data, subject to batch test reports.
| No. | Test Item | Test conditions | Unit | YHS-EPR65 | YHS-EPR80 | YHS-EPR85 | YHS-EPR90 |
|---|---|---|---|---|---|---|---|
| 1 | Appearance | - | Compliance | Compliance | Compliance | Compliance | |
| 2 | Density | g/cm³ | 0.92 | 0.92 | 0.95 | - | |
| 3 | Shore Hardness | A | 65 | 80 | 85 | 90 | |
| 4 | Tensile Strength | Mpa | 13.5 | 18 | 18.5 | 20 | |
| 5 | Elongation at Break | % | 650 | 600 | 600 | 650 | |
| 6 | Ageing | 135℃*168h | - | ||||
| Variation of Tensile strength | % | +10 | +10 | +12 | +10 | ||
| Variation of Elongation | % | -8 | -8 | -10 | -8 | ||
| 7 | Ageing | 158℃*168h | - | ||||
| Variation of Tensile strength | % | +15 | +15 | +15 | +10 | ||
| Variation of Elongation | % | -10 | -10 | -10 | -10 | ||
| 8 | Low-temperature Impact | -76℃ | - | ||||
| Failure (≤15/30) | Piece | Pass | Pass | Pass | - | ||
| 9 | Volume resistivity (20℃) | Ω.m | 5*10¹⁴ | 2*10¹⁴ | 5*10¹⁴ | 2*10¹⁴ | |
| 10 | Dielectric Loss Factor (1KHz, 1V,20℃) | - | 1.5*10⁻³ | 5*10⁻⁴ | 5*10⁻⁴ | 5*10⁻⁴ | |
| 11 | Relative Dielectric Strength (1KHz, 1V,20℃) | - | 2.3 | 2.3 | 2.3 | 2.3 | |
| 12 | Dielectric Strength (20℃) | MV/m | 30 | 32 | 32 | 32 | |
| 13 | Thermal Elongation | 200℃ 0.2Mpa 15min | - | ||||
| Elongation under Load | % | 40 | 40 | 40 | 40 | ||
| Permanent deformation after cooling | % | 0 | 0 | 0 | 0 | ||
| 14 | Thermal Elongation | 250℃ 0.2Mpa 15min | - | ||||
| Elongation under Load | % | 50 | 50 | 50 | 50 | ||
| Permanent deformation after cooling | % | 0 | 0 | 0 | 0 |
Processing Guide
Recommended Processing Parameters
1
Drying and dehumidification:
- Mix the A and B Component evenly, drop them into the hopper. Please use EVA masterbatch if color required(it should be dried). The material must be use up within 2 hours after unpacking.(It can’t be dried.)Avoid to bring the external water in during the process.
- Screw Type: Suggest to use PVC screw
- Pay-off Speed: Without the effect of smoothness and performance, the faster,the better.
2
Extrusion Temperature:
- Mark: Zone1 130±10 Zone2 160±10 Zone3 180±10 Zone4 180±10 Neck 200±10 Head 200±10
- ontrol the melt temperature of Insulation at 200±10℃ .The extrusion temperature needs to be adjusted according to the actual situation.
3
Cross-linking:
- Natural Cross-link:Temperature 15-25℃,cross-link will be finished around 7days.When temperature is higher than 25℃,cross-link will be finished around 3days.
- Water bath or Steam:Control the temperature around 60℃,cross-link will finished about 4 hours. (the thickness of the test piece is 1mm) Full performance test,water bath (steam)60℃, more than 8 hours, ensure the material is fully cross-linked.

.jpg?x-oss-process=image)