Technical Data

Technical Specifications

Typical physical property data, subject to batch test reports.

Test itemsUnitStandardTypical ValueTest Methods
Tensile strengthMPa≥1420IEC 60811
Elongation at break point%≥400600IEC 60811
Volume electrical resistivity @20℃Ω·cm≥1.0×10¹⁵8.5×10¹⁵IEC 60502
Dielectric strengthkV/mm≥2538ASTM D149
oven-aged @150℃×168h - The retaining of tensile strength%≤±30-8IEC 60811
oven-aged @150℃×168h - The retaining of elongation%≤±30+5IEC 60811
Environmental requiredConformed to RoHS、REACH
Density@23℃g/cm³0.910±0.0050.908ASTM D792
Hardness Shore D 15SecondShore D32±332ISO 868
⚠️ Data should not be specification work. In case of colored products, the values could vary slightly by color.
Recommended

Extrusion Process

The temperature for cable extrusion should be set at the situation of good cable surface performance.

ZoneZone1Zone2Zone3Zone4NeckDieEye
Temperature /℃150±10160±10170±10180±10190±10200±10210±10
Processing Guide

Recommended Processing Parameters

1

Radiation measurement

  • Recommend to irradiation dose 18-20 Mrad, according to the different wire diameter and irradiation to choose the appropriate measuring equipment, in order to achieve the best performance.It is recommended to control the thermal extension within the range of 30% -50%。
2

Storage

  • Package: 25kg per bag, Alumni-plastic inner, Kraft paper outside.
  • Storage: no rain, no direct sunlight. Dry it at 70℃~80℃ about 4 hours if the material was storage more than 3 months before used.
3

Suggestion for processing

  • The compression value of extrusion screw should be 2.5~3.5
  • The time of material heated in the barrel should not exceed 30mins, or it maybe decomposed.