Technical Specifications
Typical physical property data, subject to batch test reports.
| Test items | Unit | Standard | Typical Value | Test Methods |
|---|---|---|---|---|
| Tensile strength | MPa | ≥14 | 20 | IEC 60811 |
| Elongation at break point | % | ≥400 | 600 | IEC 60811 |
| Volume electrical resistivity @20℃ | Ω·cm | ≥1.0×10¹⁵ | 8.5×10¹⁵ | IEC 60502 |
| Dielectric strength | kV/mm | ≥25 | 38 | ASTM D149 |
| oven-aged @150℃×168h - The retaining of tensile strength | % | ≤±30 | -8 | IEC 60811 |
| oven-aged @150℃×168h - The retaining of elongation | % | ≤±30 | +5 | IEC 60811 |
| Environmental required | Conformed to RoHS、REACH | |||
| Density@23℃ | g/cm³ | 0.910±0.005 | 0.908 | ASTM D792 |
| Hardness Shore D 15Second | Shore D | 32±3 | 32 | ISO 868 |
⚠️ Data should not be specification work. In case of colored products, the values could vary slightly by color.
Recommended
Extrusion Process
The temperature for cable extrusion should be set at the situation of good cable surface performance.
| Zone | Zone1 | Zone2 | Zone3 | Zone4 | Neck | Die | Eye |
|---|---|---|---|---|---|---|---|
| Temperature /℃ | 150±10 | 160±10 | 170±10 | 180±10 | 190±10 | 200±10 | 210±10 |
Processing Guide
Recommended Processing Parameters
1
Radiation measurement
- Recommend to irradiation dose 18-20 Mrad, according to the different wire diameter and irradiation to choose the appropriate measuring equipment, in order to achieve the best performance.It is recommended to control the thermal extension within the range of 30% -50%。
2
Storage
- Package: 25kg per bag, Alumni-plastic inner, Kraft paper outside.
- Storage: no rain, no direct sunlight. Dry it at 70℃~80℃ about 4 hours if the material was storage more than 3 months before used.
3
Suggestion for processing
- The compression value of extrusion screw should be 2.5~3.5
- The time of material heated in the barrel should not exceed 30mins, or it maybe decomposed.