Technical Data

Technical Specifications

Typical physical property data, subject to batch test reports.

Test ItemUnitSpecified ValueTypical Value
Specific Gravityg/cm³—1.36
HardnessShore A/D—95A/44D
Tensile Strength≥ MPa13.8014.55
Elongation at Break≥ %300352
Thermal Aging℃×h158±2×168158±2×168
Retention of Tensile Strength / Elongation≥ %80/80103/89
Low-temperature Brittleness Test (-40℃)Failure count ≤15/300/30
Volume Resistivity @20℃≥ Ω·m1.0×10¹²3.5×10¹³
Dielectric Strength≥ KV/mm2026
Oxygen Index≥2832
Cable Flammability (UL1581)—VW-1VW-1
⚠️ Above data are properties after crosslinking Process with general extruder. Screw with L/D≥20 and low compression ratio of 1:1.2~1.5 is recommended.
Recommended

Extrusion Process

If the material has been stored in warehouse for more than two months, dry it at 70-80℃ before use.

Heat ZoneZone 1Zone 2Zone 3Zone 4HeadDie
Temperature ℃145150180180185185
Processing Guide

Recommended Processing Parameters

1

Radiation Dosage

  • Recommended radiation dosage: 12-14 Mrad; Hot-elongation after radiation shall be controlled within 25%40%.
2

Storage/Package

  • Packaging: 25 kg per bag; inner bag: aluminumfoil polyolefin film; outer package: kraft composite bag.
  • Transportation & Storage: The cable compound shall be protected from sunlight and rain during transportation. Store in clean, cool, dry and wellventilated warehouse.