Technical Data

Technical Specifications

Typical physical property data, subject to batch test reports.

Test itemsUnitStandardTypical ValueTest Methods
Tensile StrengthMpa≥9.010.8IEC 60811-501
Elongation at Break%≥120185IEC 60811-501
Volume Resistivity at 20℃Ω·cm≥1.0×10¹⁴5.6×10¹²IEC 60502
Dielectric Strength at 20℃KV/mm≥2628ASTM D149
Oxygen Index%≥3438ISO 4589
Hot Elongation (200±3℃×15min×0.2MPa) (After Irradiation)
Elongation Under Load%≤10025IEC 60811-507
Permanent Set After Cooling%≤5.01.0IEC 60811-507
Aging at 120±3℃ (After Irradiation)
Tensile Strength Variation%≤±30-5IEC 60811-401
Elongation at Break Variation%≤±30+3IEC 60811-401
Impact Brittleness Temperature (-40℃)Number of Broken Specimens / Total Specimens0/300/30ASTM D746
Corrosive Gas Performance Test after Combustion
Halogen Acid Gas Contentmg/g<5.01.0IEC 60754
pH Value—>4.36.5IEC 60754
ConductivityμS/mm<10.02.5IEC 60754
Oil Resistance (IRM902), 100±2℃×168h
Tensile Strength Change Rate%≤±40-25IEC 60811-404
Elongation Change Rate%≤±40+18IEC 60811-404
Volume Swelling Change%≤±30+21IEC 60811-404
Oil Resistance (IRM903), 100±2℃×168h
Tensile Strength Change Rate%≤±30-20IEC 60092-360 C
Elongation Change Rate%≤±30+15IEC 60092-360 C
Volume Swelling Change%≤±30+20IEC 60092-360 C
Total Mass Change Rate%≤±30+22IEC 60092-360 C
Calcium Bromide Brine Resistance, 70±2℃×56 days
Tensile Strength Change Rate%≤±25-18IEC 60092-360 D
Elongation Change Rate%≤±25+16IEC 60092-360 D
Volume Swelling Change%≤±20+12IEC 60092-360 D
Total Mass Change Rate%≤±15+5IEC 60092-360 D
Ozone Resistance (25℃, 24h, 0.03%)—No CrackingNo CrackingIEC 60811-403
Environmental Requirements—Compliant with RoHS & REACHCompliant with RoHS & REACH
Specific Gravityg/cm³1.45±0.021.45ASTM D792
HardnessShore A92±292ISO 868
⚠️ Data should not be specification work. In case of colored products, the values could vary slightly by color.
Recommended

Extrusion Process

Note: The temperature for cable extrusion should be set at the situation of good cable surface performance.

ZoneZone1Zone2Zone3Zone4NeckDieEye
Temperature /℃120±10140±10150±10160±10170±10170±10170±10
Processing Guide

Recommended Processing Parameters

1

Radiation measurement

  • Recommend to irradiation dose 10-12 mrad, according to the different wire diameter and irradiation to choose the appropriate measuring equipment, in order to achieve the best performance.It is recommended to control the thermal extension within the range of 15% -25%。
2

Storage

  • Package: 25kg per bag, Alumni-plastic inner, Kraft paper outside.
  • Storage: no rain, no direct sunlight. Dry it at 60℃~70℃ about 4 hours if the material was storage more than 3 months before used.
3

Suggestion for processing

  • The compression value of extrusion screw should be 1.2~2.0
  • The time of material heated in the barrel should not exceed 10mins, or it maybe decomposed.